vrijdag 24 oktober 2008

Troubleshooting

I noticed the following problems :

- The solo and principal group sound less loud then the tibia's
- Percussion switch and slider do not seem to have any effect
- The vibrato slider does not seem to have any effect
- The light of the on/off switch does not work
- The light in the volume pedal does not work

At first I suspected all these problems had a different cause. But studying the schematics learned me all these problems had something in common.

They are fed by the -20V supply off the power supply. Doing some measurements on the power supply I found out the -20V supply was completely dead.



Then I found a fried resistor (picture red arrow). Seems I have shorted the -20V circuit while working on the organ. I remembered the first day I was working on the organ the power light was still working, at some point it stopped working. I thought it was just the bulb that had gone dead.
Exchanging the resistor with a new one fixed the problem.

3 opmerkingen:

U RESTORATION 3.10 zei

HI I GIT THE SEEM PROBLEM ON THE U 310 WHOSE RESISTANCE VALUE??
all the unit seem making the seem sound white chanel doesn t effect the unit/

U RESTORATION 3.10 zei

HI I GIT THE SEEM PROBLEM ON THE U 310 WHOSE RESISTANCE VALUE??
all the unit seem making the seem sound white chanel doesn t effect the unit/

U RESTORATION 3.10 zei

HI I GIT THE SEEM PROBLEM ON THE U 310 WHOSE RESISTANCE VALUE??
all the unit seem making the seem sound white chanel doesn t effect the unit/